Solar radiation chamber
Main Technical Parameter | ||||||||||
Temperature range | 10℃~+70℃(without lighting) |
Remark: 1 All tested in empty chamber condition (except indicated), according to GB/T5170-2008 2 Data for air cooling chamber is tested when the room temperature is 25℃, with good ventilation; normal use in the event of room temperature between 25℃ and 35℃, with some influences on low-temperature range, cooling down rate and thermal load capacity. 3 Data for water cooling chamber is tested under the conditions that water temperature is no more than 28℃, water pressure is between 0.2MPa and 0.6MPa and the pressure difference between in and out water is no less than 0.2MPa |
||||||||
Temperature fluctuation | ≤±0.5℃(without lighting) | |||||||||
Temperature uniformity |
≤2℃(without lighting) | |||||||||
Temperature deviation | ±2℃(without lighting) | |||||||||
Humidity range | 40%~98%RH(without lighting) (See Humidity Range Drawing) | |||||||||
Humidity deviation |
+2~-3%(>75%RH), ±5%(≤75%RH)(without lighting) |
|||||||||
Heating up time | ≤60min(room temp. ~+70℃) | |||||||||
Illumination intensity | (700~1120)±10% W/m2(adjustable) | |||||||||
Illumination time | 0~99h99min adjustable | |||||||||
During the illumination, the temperature in the chamber should rise to the setting temperature control value with an almost linear speed and keep it stable (the typical setting value is + 55 ℃ and 40 ℃). During no illumination, the temperature in the chamber should drop to the setting temperature control value with an almost linear speed and keep it stable (the typical setting value is +25℃). Under different test procedures, the relations between the temperature, irradiation and time during testing are shown in Chart 2. | ||||||||||
Spectral energy and tolerance: should meet the requirements in Table 1 | ||||||||||
Test duration | Can adjust in the range of 0~999h, and the test can be performed automatically according to the following test procedures: | |||||||||
Test procedure A: 24 hours a cycle, 8 hours illumination and16 hours no illumination. Test cycle can be set. | ||||||||||
Test procedure B: 24 hours a cycle, 20 hours illumination and 4 hours no illumination. Test cycle can be set. | ||||||||||
Test procedure C: Continuous illumination. Test cycle can be set. | ||||||||||
Light tube cooling | Air cooling(The effective use life of metal halide lamp tubes is 800~1000 hours under normal use) | |||||||||
Air speed | The air speed of chamber is adjustable in the range of 0.5~1.5m/s via the converter. | |||||||||
The comparison tables for air speed and converter are attached to the equipment instruction book. | ||||||||||
Spectral energy and tolerance: should meet the requirements in Table 1 (Chart 3) | Spectral region | Ultraviolet B | Ultraviolet A | Visible light | Infrared | |||||
Band width µm | 0.28~0.32 | 0.32~0.40 | 0.40~0.52 | 0.52~0.64 | 0.64~0.78 | 0.78~3.00 | ||||
Radiation intensity W/m2 |
5 | 63 | 200 | 186 | 174 | 492 | ||||
Tolerance % | ±35 | ±25 | ±10 | ±10 | ±10 | ±20 |